Detailed
MTC series water temperature controller,which are used to heat up the mould and maintain temperature, and they can be used in other similar applications. High temperature water from the mould is returned to the cooling tank and cooled direct cooling. It is then pressurised by the high-pressure pump, sent to the heating tank and finally to the mould with a constant temperature. The P.I.D temperature controller can maintain an accuracy of ±0.3℃.
Features
P.I.D. multi-stage temperature control system can maintain a mould temperature with accuracy of ±0.3℃.
Adopts high efficiency water cycle pump, which can meet the demands of temperature control for precise moulds and mould loop with minor diameter to achieve precise temperature control and high efficient heat exchange. Pump inside adopts stainless steel to avoid explosion.
Multiple safety devices including power phase error protection, pump overload protection, overheat protection and low level protection that can automatically detect abnormal performance and indicate this via visible alarm/error code.
The heating temperature can reach 120℃.
Equipped with high pressure protection, safety pressure relieving, automatic water supplying and air exhausting.
Water manifolds and Teflon hose are optional.
Technical Parameter
Model | MTC |
1205G | 1210G/S | 1220S | 1230W | 1610W | 1620W | 1810W |
Power supply | AC380V 3PH 50HZ |
Max.Working Temp | 120℃ | 160℃ | 180℃ |
Lowest working temp. | Water supply temp.+3℃~+10℃ |
Medium | Water |
Heating energy | 6KW | 9KW | 12KW | 18KW/24KW | 9KW | 12KW | 12KW |
Cooling method | 5400Kcal/h | 7200Kcal/h |
Cooling Method | Direct cooling | Indirect cooling |
Accuracy | ±0.3℃ |
Pump Power | 0.5HP | 1HP | 2HP | 3HP | 1HP | 2HP | 1HP |
Pump flow rate& Pressure | 42L/min2.6KG/CM2 | 56L/min2.6KG/CM2 165L/min2.6KG/CM2 | 110L/min2.6KG/CM2 235L/min2.6KG/CM2 | 315L/min2.6KG/CM2 | 56L/min2.6KG/CM2 | 165L/min2.6KG/CM2
| 165L/min 2.6kg/CM2 |
Energy Consumption | 6.5KW | 9.75KW | 13.5KW | 20.25KW | 9.75KW | 13.5KW | 12.75KW |
Cooling water pressure require | 1.5Kfg/cm2Min. | 2.51.5Kfg/cm2Min. | 3.51.5Kfg/cm2Min. |
Cooling water pipe size | 1/2″PT |
In/outlets | 2/2 3/8″PT | 4/4 3/8PT or 1/1 1 inch PT |
Dimensions | 800*270*570 | 780*270*600 | 900*290*670 | 1100*350*810 | 1000*320*730 | 1000*320*780 | 1000*320*780mm |
Weight | 45KG | 53KG | 60KG | 101KG | 70KG | 80KG | 92KG |